Institutional Repository

Structural characterization and evaluation of the bio-adhesive strength and temperature effects on latex extracted from the candelabra tree

Show simple item record

dc.contributor.advisor Ngwangwa, H. M.
dc.contributor.advisor Tebeta, R. T.
dc.contributor.author Madiba, Alpheus
dc.date.accessioned 2026-10-19T12:15:29Z
dc.date.available 2026-10-19T12:15:29Z
dc.date.issued 2026-08
dc.identifier.uri https://ir.unisa.ac.za/handle/10500/33166
dc.description.abstract Adhesives are used in applications where substrates are bonded together under variable applied loads. Adhesive materials are in demand across many industries, including packaging, automobiles, aviation, aerospace engineering, and construction. Rather than using solvent-based synthetic adhesives, this paper focuses on biodegradable bio-adhesives extracted from plant-based sources that bond to paper substrates. The aim of the research paper was to develop methods to extract latex from plant-based materials, process latex to produce a bio-adhesive material, bond surfaces of different substrates, and examine the influence of temperature on this bio-adhesive material. To assess the mechanical properties of bio-adhesive materials, T-peel and single-lap shear tests were conducted. Thermal analysis was performed via differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and rheological testing. Latex extraction involves using a laboratory blender to process candelabra tree branches into small pieces, resulting in white sap. This material is refined through a filtration process to remove impurities. Purified latex is cured at room temperature, where it changes from a liquid 0 0 0 0 to a solid state. By applying heat at varying temperatures of 100 C, 110 C, 120 C, 130 C, 0 0 140 C, and 150 C, this latex is transformed into a bio-adhesive material. Thermal analysis and bio-adhesive properties were investigated under varying temperature limitations and under chemically controlled conditions using TGA, DSC, and rheological testing methods. The testing conditions remained constant, guaranteeing the steadiness and dependability of the data measured. The TGA-DSC testing method ensured that weight changes were correlated with thermal events and improved material stability assessments. Rheological measurements investigated the association between shear rate and shear stress of bio-adhesive material in a state of laminar flow. It also investigated other factors that cause material distortion. Mechanical properties were evaluated via T-peel and single-lap shear examinations to investigate bio-adhesive shear strength in paper-to-paper specimens. Using tensile testing equipment, a single lap-shear test was conducted to examine bio-adhesive mechanical effects. The T-Peel test was conducted using a U-Stretch Mechanical Test System. For both mechanical tests, a steady application of force to the two peel arms at opposite ends was used to obtain analytical data under varying temperature parameters of the processed bio-adhesive material. In the experimental method, only processed latex was used, whereas in the thermal analysis method, both unprocessed and processed latex were used. 0 TGA results indicated that 130 C is the temperature at which the bio-adhesive material achieves higher oxidation, with 1,12% weight loss at a furnace temperature of 3200C. Unprocessed latex materials require a higher oxidation temperature than treated bio-adhesive materials. DSC results indicated that the 1400C bio-adhesive material performed better than other bio-adhesive materials. The maximum heat flow value of this bio-adhesive at 2000C is 1,2 W/g. Rheometer results showed that the 1000C-processed material is the most robust, with a high storage modulus of 39 Pa and a peak of 124 Pa. Single-lap shear test results showed that the material processed at 110°C produced the highest signal-to-noise ratio of 24,69 and the highest average elastic modulus of 17,333 MPa, indicating superior stiffness, strength, and rigidity. T-peel test results showed that higher-temperatureprocessed bio-adhesive materials could achieve higher peeling forces than materials processed 0 at a lower temperature. In this case 130 C is a material with a much higher average peeling strength of 529,22 N/m. Thermal results indicated that bio-adhesives can maintain thermal stability while undergoing multiple decay stages. Unprocessed latex materials require more energy to break down and have higher oxidation temperatures than treated bio-adhesive materials. The elastic properties of bio-adhesive materials are improved when processed at low temperatures. According to the results, bio-adhesive materials processed at low temperatures exhibit a steady recovery rate, whereas those processed at high temperatures show a rapid recovery rate. According to mechanical results, the bio-adhesive exhibits elastic deformation properties as indicated by graphical linear behaviour and enhanced peeling strength as processing temperature increases. This provides further validation that at higher temperatures, processed bio-adhesive materials with greater UTS and lower Elastic Modulus can endure significant stresses, strains, and applied forces without breaking or losing their bond. This investigation and material characterization will help in understanding the mechanical and thermal properties and performance of this novel bio-adhesive material. These data will guide the foundation for processing raw latex materials, and characterize the bio-adhesive behaviour linked to changes in processing temperature. The major contribution will be to environmental impact because bio-adhesive materials are biodegradable. Moreover, the life cycle assessment compares its environmental footprint with that of conventional synthetic adhesives, highlighting improvements in recyclability and reduced toxic emissions. en_US
dc.format.extent 1 online resource (xv, 142 leaves) : color illustrations
dc.language.iso en en_US
dc.rights ©Unisa
dc.subject Single-lap shear test en_US
dc.subject T-peel test en_US
dc.subject Thermogravimetric analysis (TGA) en_US
dc.subject Differential scanning calorimetry (DSC) en_US
dc.subject Rheological testing en_US
dc.subject Candelabra tree latex en_US
dc.subject Bio-adhesives en_US
dc.subject.lcsh Mechanical engineering
dc.subject.lcsh Adhesives
dc.subject.lcsh Latex
dc.subject.other UCTD
dc.title Structural characterization and evaluation of the bio-adhesive strength and temperature effects on latex extracted from the candelabra tree en_US
dc.type Thesis en_US
dc.description.department Mechanical, Bioresources and Biomedical Engineering
dc.description.degree Masters in Engineering (Mechanical)
dc.date.updated 2026-10-16T06:48:15Z


Files in this item

This item appears in the following Collection(s)

  • Unisa ETD [13659]
    Electronic versions of theses and dissertations submitted to Unisa since 2003

Show simple item record

Search UnisaIR


Browse

My Account

Statistics